Voltage probe body *1 CK-605 (USB 5V adapter) *1 CK-261 (alligator clips) *1 pair /// CK-262 (alligator clips) *1 pair CK-281 (insulated piston probe clips) *1 pair CK-284A (test hooks) *1 pair CK-301 (input extension cable) *1 pair CK-310 (BNC output cable) *1 Banana jack female socket (CK-293) *2 CK-315B (USB connection cable) *1 User manual *1 Warranty card *1 Factory inspection report *1
Product Specifications

【7000Vpk/100MHz】
CN¥11,500.00

【700Vpk/100MHz】
CN¥4,280.00
| Item | Detail |
|---|---|
| 50X | ±150 V |
| 100X | ±350 V |
| 500X | ±1500 V |
| Item | Detail |
|---|---|
| 100X | ±350 V |
| 1000X | ±3500 V |
| Item | Detail |
|---|---|
| 100X | ±700 V |
| 1000X | ±7000 V |
| Item | Detail |
|---|---|
| DP6150 | 5 MΩ |
| DP6350 | 5 MΩ |
| DP6700 | 20 MΩ |
| Item | Detail |
|---|---|
| DP6150 | 10 MΩ |
| DP6350 | 10 MΩ |
| DP6700 | 40 MΩ |
| Item | Detail |
|---|---|
| DP6150 | <4 pF |
| DP6350 | <4 pF |
| DP6700 | <5 pF |
| Item | Detail |
|---|---|
| DP6150 | <2 pF |
| DP6350 | <2 pF |
| DP6700 | <2.5 pF |
| Item | Detail |
|---|---|
| 50X | <50 mV |
| 100X | <100 mV |
| 500X | <300 mV |
| Item | Detail |
|---|---|
| 100X | <220 mV |
| 1000X | <600 mV |
| Item | Detail |
|---|---|
| 100X | <220 mV |
| 1000X | <1.2 V |
| Item | Detail |
|---|---|
| 50X | ≥150 V |
| 100X | ≥350 V |
| 500X | ≥1500 V |
| Item | Detail |
|---|---|
| 100X | ≥350 V |
| 1000X | ≥3500 V |
| Item | Detail |
|---|---|
| 100X | ≥700 V |
| 1000X | ≥7000 V |
| Item | Detail |
|---|---|
| 50X | 9 ns |
| 500X | 7.5 ns |
| Item | Detail |
|---|---|
| 100X | 9.3 ns |
| 1000X | 7.4 ns |
| Item | Detail |
|---|---|
| 100X | 9.3 ns |
| 1000X | 7.2 ns |
The probes feature high-voltage differential input ports rated up to 1500 V.
The attenuation ratio must be set on the oscilloscope according to the probe setting.
Bandwidth selection feature allows switching between full bandwidth and 5 MHz bandwidth limit to reduce high-frequency interference.
Overload alarm function provides audible and visual alerts when measurement exceeds range; audible alarm can be toggled ON/OFF.
Standard BNC output interface compatible with oscilloscopes requiring 1 MΩ input impedance; 50 Ω input impedance on oscilloscope will halve output signal.
Power can be supplied via USB adapter, oscilloscope USB port, or portable USB power bank for field testing.
Alligator Clips (CK-261, CK-262, red/black pairs)
Piston Clips (CK-281, red/black pair)
Test Hooks (CK-284A, red/black pair)
Input Extension Cable (CK-301, red/black pair)
Coaxial Output Cable (CK-310)
USB Cable (CK-315B, AM-BM, 1.5 m)
Banana Jack Female Socket (CK-293)
USB 5V/2A Adapter (CK-605)